How to set maxcc in jcl

WebUsing the SET command and MAXCC Parameter z/OS DFSMS Access Method Services Commands SC23-6846-01 In this example, if the maximum condition code is 0, the program lists an entry from a catalog and prints a data set. If the maximum condition code is not 0, … WebDec 8, 2011 · The STATUS command gives the status of jobs, if they are executing or in output queue after completion, So I think we don't have to wait till the job is completed. @kokwind. In your code, Code: SAY LOG.2. PARSE VAR LOG.2 "JOB" JOBID MESSAGE. SAY "JOB "JOBNAME" ("JOBID") "MESSAGE. OUTPUT: Code:

SET Command - IBM

WebDec 15, 2011 · MY requirement is to get same record counts using JCL - Syncsort. MY Input File contains the packed decimal values in 58-60 position. I need to get the record count when the input in between 01 and 05 range. Actually I tried to convert PD values into ZD and compare with C'01' and C'05'. I could not get the result. WebMay 9, 2012 · So you have a DELETE - it is returning a code of 8 - probably because the dataet to be deleted does not exist. It does not exist - you were trying to delete it - no problem so set the return code to 0 (SET MAXCC+0) and continue with the next operation. If you want to stop the 8 happening in the first place then you need to define a dataset to ... phobia of dark windows https://tri-countyplgandht.com

setting maxcc conditionally in jcl -IBM Mainframes

WebJul 10, 2024 · The following requirements can be met using below mentioned JCL utilities: 1. Need to check if a data set is empty or not. If it’s empty I want to skip all other steps. 2. Need to skip certain steps in my job if the input is empty. This would be easiest if a utility would generate a non-zero RC if the input is empty. 3. WebUsing the SET command and MAXCC Parameter In this example, if the maximum condition code is 0, the program lists an entry from a catalog and prints a data set. If the maximum condition code is not 0, set the maximum condition code to 8. IF MAXCC=0 THEN DO LISTCAT CATALOG (AMASTCAT/MST27) ENT (MN01.B005) PRINT INFILE (AJK006) END WebUse the SETRC function to set the job step return code to a specified value. Use conditional parameters to set the return code based on an existing return code value. Syntax .-IFOP=EQ-. >>-SETRC--RC=rc--+---------+--+----------+--------------------->< +-IFOP=GE-+ '-IFRC=rc2-' tswelopele roads and earthworks

Submitted a job through REXX -IBM Mainframes

Category:SET Return code for MAXCC in JCL - JCL - IBM …

Tags:How to set maxcc in jcl

How to set maxcc in jcl

eliminate the return code 8 - JCL - Page 2 - IBM Mainframe Forum

WebMar 25, 2014 · The short answer to your question is No. You can't magically pass the highest Return Code, or Return Code from a previous step, to a program just with JCL. The longer answer is Yes, it will probably be possible to do what you want, however you have asked us how to provide the solution you have come up. WebSYS1.IMAGELIB data set open with the IMGLIB macro when checkpoint taken. Programmer Response: Ensure that all IMAGELIB DCBs are closed prior to issuing CHKPT. See also IMGLIB. 251: S23F: A data set that was not a checkpoint data set at checkpoint time was found to be open as a secure checkpoint data set at restart time.

How to set maxcc in jcl

Did you know?

WebUse the SET command to change or reset a previously defined condition You can end all processing by setting MAXCC or LASTCC to 16. The syntax of the SET command is: … WebMay 3, 2007 · Can anyone please help to find how to set MAXCC to 24 in jcl . I am getting a RC = for this job . my task is to set the MAXCC to 24 whenever maxcc is between 1 &amp; 19, I have already done this using IDCAMS, but I am asked to find a alternative. Back to top agkshirsagar Active Member Joined: 27 Feb 2007 Posts: 691 Location: Earth

WebThe purpose of the IDCAMS step would be to delete the dataset. The IDCAMS DELETE command will give you a bad return code (12, if memory serves) if the dataset doesn't exist, but you can modify that by coding IF MAXCC=12 THEN SET MAXCC=0 under those circumstances. Update per additional restrictions on what's allowed WebJun 23, 2024 · If one of the data sets isn't there, you can suppress the CC 8 by using an IF LASTCC = 8 after the DELETE or IF MAXCC = 8 as the last card. (Note that 8 can be returned for other reasons other than not in catalog.)

WebMay 12, 2009 · maxcc=12 while using IEBGENER by weishi » Tue May 12, 2009 5:47 am Hi, when I used IEBGENER to copy a PS, maxcc=12,but the data set was copied and no errors encountered, I want to know the reasons,thanks. my jcl: Select all //QR115 JOB ,'QR115',MSGLEVEL= (1,1),MSGCLASS=A, // CLASS=A,NOTIFY=QR115 … WebSep 6, 2011 · Hence i would like to go with execute IDCAMS or other utility to set the MAXCC to 4 or less then 4 as return code. My JCL will be like below 1. STEP01 --&gt; This step will …

WebThe SET command may be used to set either the LASTCC value or the MAXCC value to a specific value. Frequently the SET command is used to reset the return code (s) to a value of 0 following an expected warning level error condition. Example: Let us see an example how to delete and define VSAM dataset in single JCL step using IF statement. phobia of dark placesWebJan 25, 2024 · IF LASTCC =8 ; SET MAXCC=0. Step 2: Create a new VSAM File DEFINE VSAM-FILE_NAME (COND=(0,LT,STEP1) ... Step3: Next, you must run a JCL command (IDCAMS - Define Cluster) with step-2 results/output (sorting mechanisms) as input. Step4: Finally, to load the flat file into VSAM, use the IDCAMS REPRO command. phobia of deez nutsWeb&MAXCC contains the highest return code returned by a nested CLIST or by a TSO/E command, subcommand, or CLIST statement in the currently executing CLIST. &MAXCC is not set when a subprocedure returns to the CLIST. You can use &MAXCC with &LASTCC to determine error conditions. phobia of dental treatmentWebMay 13, 2011 · How to setup MAXCC of JCL using IDCAMS? You just need to code SET MAXCC= in the SYSIN dataset of IDCAMS. What are the limits for SET … phobia of disappointing othersWebMay 10, 2024 · The solution is to add an IDCAMS step at the end of your jobs JCL, use a LISTC ENT on a dummy dataset and set the MAXCC to 0000. Then add to the jobcard, JOBRC=LASTRC which instructs the job to use the last return code of the job to set the jobs final return code. In this case, it will be zeros as instructed by the IDCAMS. phobia of diceWebWhen we want to submit a JCL(JOB), we give the command ‘SUB’ or ‘SUBMIT’. ... MAXCC=0000 CN(INTERNAL). If you notice, we can get MAXCC=00 or 04 or 08 or 12 or 16 etc. MAXCC is maximum condition code which is the maximum return code from any step. Return code is the status of each step. Follow @tutorial_brain. Various Return codes of … phobia of dentistWebExplanation: In this example, After STEP01 is completed we check the Return code of STEP01 step. if return code is zero then STEP02 step will execute else step STEP03 will be executed. Tips: IF RC = 0 THEN IF STEP1.RC < 12 THEN If you not given the stepname, then the highest return code from all job steps is taken for checking. tswelopele technologies